The tool has the following modifications by max operating temperature T max and upper value of borehole hydrostatic pressure Pmax :
by temperature: 120, 150, 175, 200 °С,
by pressure: 80, 100, 120, 140 МPа.
Designed for independent measurement of four radii in two perpendicular planes.
Used for logging of open and cased oil and gas wells; operates with a three-conductor carrying logging cable up to 7000 m long and log recorders that provide for command transfer and data receipt in “Manchester-2” code.
Applications:
borehole diameter measurement;
keyseat detection;
annular volume calculation;
well technical condition control etc.
The measurements are held with the help of displacement resistive sensors, each sensor is mechanically connected with its arm.
Measured parameters |
Range |
Error |
Arms opening radii |
50÷300 mm |
±3 mm |
Borehole diameter |
100÷600 mm |
±5 mm |
General specifications |
Tool length, mm |
4200 |
not more than |
Tool diameter, mm |
76 |
not more than |
Tool weight, kg |
82 |
not more than |
Power supply:
supply voltage, V
supply frequency, Hz
Power consumption, V·A:
in measuring mode
in drive operation mode |
220
50
5
90 |
10%
1%
not more than
not more than |
Drive control |
multiple, at the command from the surface |
|
Arms opening (closing) time, min |
2 |
not more than
|
Borehole diameter, mm |
100÷600 |
|
Logging speed, m/hr |
up to 2000 |
|
Combinability |
feed-through |
|
Location in the borehole |
clamped |
|
|